The European Compact Transformer Power Preinstalled Chamber Type Substation, Unitzed Substation, Transmission Substation, 11kv, 12kv

The European Compact Transformer Power Preinstalled Chamber Type Substation, Unitzed Substation, Transmission Substation, 11kv, 12kv

Contact to know the price
Product specifications
  • Altitude:≤2000m
  • Ambienttemperature:-35ºC~+40ºC
  • Relative humidity: daily≤95%, monthly ≤90%
  • Installation site should be free of fire, explosive danger, serious pollution, chemical corrosion or severe vibration.
  • Monthly average≤90%
  • Seismic capacity: 8 degrees
  • Standard :GB 17467-2010 ,GB 50053-1994 
  • Quality standard: ISO 9001:2015; ISO 14001:2015 

Introduction of The European Compact Transformer Power Preinstalled Chamber Type Substation, Unitzed Substation, Transmission Substation, 11kv, 12kv


The European Compact Transformer Power Preinstalled BOX type substation(YBW series) is a complete set of new power transformer equipment ,which is widely used in power transformation system ,it’s a combination of oil-immersed sealed power transformer and high and low voltage electrical components.

 Through structure optimization, the switchgear shall be miniaturized to extreme extent which greatly reduce the occupied area of the combined transformer with such advantages as small volume, low noise, reliable power supply, reasonable structure, convenient for installation, easy for operation and capable of going deep into the load center to maximum extent, etc.It is widely used in residential quarters commercial centers stations industrial and mining enterprises airports railroads schools hospitals, high-rise buildings and places.Standard of production & testing:IEC62271-1,IEC62271-200,IEC62271-202,IEC60076,IEC61439, IEC60529,IEC62262, IEC60721.

European Type Boxes Substation
European Type Boxes Substation

Advantages Of Yb Series European Style Compact Substation

-The product consists of HV distribution unit, and LV distribution unit and is divided into HV chamber, transformer chamber and LV. The HV chamber has complete functions, it with HXGN-10 ring main unit forms the primary supply system, may be arranged into several supply modes(ring main supply, terminal supply and dual-source supply) and also may be provided with HV metering elements to meet requirements on HV metering. Model S9,S11 and other low oil-immersed transformers or dry transformers else may be selected. The transformer chamber is designed to have automatic forced air cooling system and lighting system. The LV chamber can constitute user-required power supply schemes in a panel type or cabinet type structure, provide several functions(power distribution, lighting distribution reactive power compensation, and metering of electrical power) to meet users’ different requirements. And facilitate supply management and improve power supply quality.

-The HV chamber is compact in structure and is provided with mis-operation preventive interlocking function. Each chamber has automatic and forced lighting device. In addition, all elements in HV and LV chamber are reliable in performance and easy in operation, which makes the products safe and reliable and easy in operation and maintenance.

-It adopts both natural ventilation and forced ventilation to each good ventilation and cooling effects. The transformer chamber and LV chamber are provided with air ducts. The blower fan has a temperature controller to automatically start and stop as per the preset temperature, thus ensuring on-load running of transformer.

-Cable head with two types: 200A elbow connector and 600A “T” type fixed cable connector. Both can be equipped with all insulated ZnO lightning conductors. 200A elbow connector can use with load plug and with the function of insulation switch.The casing body prevents rain water and foreign matter from entrance and it is made of hot-galvanized color steel sheet or anti-rust aluminum alloy sheet and subjected to anti-corrosin treatment. It looks artistic, keeps long-term corrosion, water and dust-proof under outdoor conditions, and prolong service life of transformer.-Cable head with two types: 200A elbow connector and 600A “T” type fixed cable connector. Both can be equipped with all insulated ZnO lightning conductors. 200A elbow connector can use with load plug and with the function of insulation switch.

The Box European Type Electrical Panel gets quality standards of product

Huarui’s European Type Power Distribution Boxes Transformer Substation passes strict quality control at all stages from input to output, ensuring to meet the stringent requirements of International standards fully: MA,ilac-MRA,ilac-MRA,CANS

1. Quality management system ISO 9001: 2015

The operation of the whole HuaRui system is strictly controlled and managed. This ensures the quality of products in all stages, from receiving customer requests to design, materials, production, installation, testing, packaging, delivery, after-sales, all of which operate under strict and logically linked processes.

2. Environmental management ISO 14001: 2015

HuaRui pioneered the application of the environmental management system ISO 14001: 2015. The implementation of this process is a testament to HuaRui’s responsibility to a wide range of customers. HuaRui commit to providing high-quality technical products that are most environmentally friendly. 

3. Accreditation certificate ISO / IEC 17025: 2017

ISO / IEC 17025: 2017 certification confirms that HuaRui’s technical quality meets the requirements of all specific international standards for testing and calibration laboratories. All HuaRui’s products are fully tested in a qualified testing room before leaving the factory, ensuring stable quality and providing absolute peace of mind for customers.

Quality certifications of HuaRui's product
Quality certifications of HuaRui’s product

The technical parameters of the form are for reference only.Customized products can consult online customer service!

Medium voltage unitRated frequencyHz[ 50
Rated voltagekV7.2 12 24 40.5
Rated current of main busA6301250 1 600
Rated short-time withstand current I durationkA/s20/4 25/331.5/4
Rated peak withstand currentkA506380
1min power frequency withstand voltage (to-ground/between open contacts)kV32/3642/48 65/79 95/115
[ ightning impulse withstand voltage (to-ground/between open contacts)kV60/70 75/85 125/145 185/215
Rated short-circuit breaking currentkA20 25315
Ground loop short-time withstand current/ durationkA/s20/220/4
Rated short-circuit making current of main loopkA50 63 80
Rated active load breaking currentA630
Rated closed loop breaking CcurrentA630
Rated transfer currentA1700
Mechanical life peroidtimes30005000 10000
Low voltage unitRated frequencyHz50
Rated voltagekV0.4/0.23
Rated insulation voltageV690
Rated current of main loopA100~ 3200
Rated short-time withstand currentkA/s30/1 50/1 1 00/1
Rated peak withstand currentkA63 105 176
5s power frequency withstand voltagekV2.53.75
Transformer unitRated frequencyHz50
Rated voltagekV7.212 2440.5/0.4
Rated capacitykVA30~ i 600
1min power frequency withstand voltagekV25/2035/28 55/5085/75
Lightning impulse withstand voltagekV60 75 125 170
Impedance voltage Tapping range%4~6 +x2.5% +x5%
Connection groupY,yn0 D.yn11
TypeOil-immersed type; dry type
Cabinet bodyIP code of HV and LV chambersIP33D
IP code of transformer chamberIP23D
Sound level (oil-immersed type/cry type) dB s50/55

FAQ

Our products and business spread over more than twenty provinces and cities in the east, north, southwest and northwest of China and more than ten countries and regions all over the world, so that people of different cultures and different skin colors can enjoy the energy -saving electrical products and services provided by Huarui Electric.

1.Q: Are you manufacturer?

A: Yes, we are manufacturer. Our factory is in Liaocheng City, Shandong Province.

2.Q: Can I get guarantee of products?

A: Yes, every product is 1 year quality warrantee under customer correct using the products.

3. Q: What about the production?

A: In general, it take 2~6weeks and it depend on the different style.