Global Standard Container Size (practical recommendation collection)
(Data from the 2022 years of foreign companies, is collected by Huarui Electric Mr.Ben, some data will be deviated, subject to shipping company)
| Type | Size | Length (mm) | Width (mm) | Hight (mm) | Volume (cu.m) | Load (T) | Remark |
| General cabinet | 20GP | 5898 | 2352 | 2393 | 33.2 | 27 | |
| 40GP | 12032 | 2352 | 2393 | 67.7 | 28 | ||
| High cabinet | 40HC/HQ | 12032 | 2352 | 2698 | 76.3 | 28 | |
| 45HC/HQ | 13556 | 2352 | 2698 | 86 | 29 | ||
| Open cabinet | 20’OT | 5895 | 2350 | 2351 | 32.5 | 28 | The ceiling can be used, which can be super high |
| 40’OT | 12025 | 2350 | 2351 | 66.4 | 30.4 | ||
| Flat bottom cabinet | 20’PC | 5920 | 2227 | 2233 | – | 28 | Load large transformer |
| 40’PC | 12028 | 2383 | 1950 | – | 36 |
Packing description:
- In any case, the weight of the goods cannot exceed the maximum load of the container.
- Loading should be loaded, and the load in containers must not be partial or one side.
- Each purchase of a batch of goods need to be filled (shipping company requirements), the loading is still taken: the loading is double-door open (including container number), left door closing (including container numbers), right door close (padlock 3 photos.
- 2T fork-shaped loading and unloading truck in the box

1.bulk cargo transformers:
Single 200kva transformer, tap box (plywood) 300 yuan / table; large-capacity transformer packaging needs to be expected.
2.Full box transformer:
- Single 500kg transformer is recommended below the slot steel 50x37x4.5mm + angle steel 40x40x5mm welding fixed, suggest that the second layer of 4 / group (or 2 / group). Material + labor cost = 250 / stage.
- Single 500kg transformer is recommended for trough 63x40x4.8mm + angle steel 50x50x5mm welding, suggesting 2 sets of 2 / group. Material + labor cost = 300 / stage or more.
- packing requires that each set of shelves is welded with angle tones (for disassembly), so that all shelves are reinforced into one.
- If there is a gap, there is a gap, it needs to be reinforced to prevent the tilt collision of the goods.
- large-capacity can’t code two-layer transformers can be fixed around the ≥φ12mm wire rope.
3.Switch Cabinet & Distribution Box
- Corrugated with corrugated cardboard (1cm thick) with customized company logo, fixed to prevent scraping.
- Close to the equipment, and the container gap is reinforced with corrugated cardboard, and the gap is larger with a wooden board or wooden frame.